Sign In | Join Free | My uabig.com
China Shenzhen Veikong Electric Co., Ltd. logo
Shenzhen Veikong Electric Co., Ltd.
Shenzhen Veikong Electric Co., Ltd.
Verified Supplier

4 Years

Home > MPPT VFD Solar Pump Inverter >

LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance

Shenzhen Veikong Electric Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance

Brand Name : VEIKONG

Model Number : VFD500-PV

Certification : CE

Place of Origin : China

MOQ : 5

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 15000pcs per Month

Delivery Time : depend on the order quantity

Packaging Details : the power less than 45kw use Carton, starting from 45kw use Wooden case

Product Name : solar pump inverter

Voltage : 220v/380v

frequency : 50hz/60hz

Display : LED+LCD

Protection : ip20 and ip65

Color : White and blue

Brand : VEIKONG

Original : China

OEM : Supported

MOQ : Negotiable

Contact Now

LCD MPPT VFD Solar Pump Inverter GPRS solar vfd for pump solar irrigation system

VEIKONG IS Solar Ac Pump Controller chinese manufacturer

Performance features:(220v 0.75kw-75kw, 380v 0.75kw-250kw)

Product Details and Features:

1. Support single phase/three phase 220V, and three phase 380V solar water pump inverter, power from 0.75KW to 160KW.

2. Simply connect the photovoltaic panel to the solar water pump inverter, and the PV pump c be automatically started after power-on.

3. It has protection functions such as PV over-voltage protection, over-temperature automatic protect, etc., which can effectively extend the life of the product.

4. Ensure solar power tracking efficiency can reach 99%.

5. All series of products can realize automatic switching of PV DC input and grid AC input, which can meet 24 hours of no care work.

6. Supports IP20 and IP65 grade cabinet solutions.

7. LCD display, GPRS module, Output reactor Accessories.

Electrical Specifications

PV input
Maxiumum input DC voltage 400V DC
Recommended MPPT voltage range 250~350V DC
Recommended input Operation Voltage 310V DC
Grid or backup generator input
Input voltage Single phase 220V(-15%~30%)
Output Specification
Rated output voltage 3PH 220V
Output frequency 0~500.00Hz (default: 0~50.00Hz)
380V Solar Pumping Inverter
Input Specification
PV input
Maxiumum input DC voltage 800V DC
Recommended MPPT voltage range 450~650V DC
Recommended input Operation voltage 540V DC
Grid or backup generator input
Input voltage Three phase 380V(-15%~30%)
Output specification
Rated ouput voltage 3PH 380V
Output frequency 0~500.00Hz (default: 0~50.00Hz)
Protection
Built-in Protection Lighting Protection ,over-current, overvoltage, ouput phase lose, under-load, under-voltage, short circuit , overheating, water pump run dry etc.

General Parameters
Application site No direct sunshine, no dust,corrosive gas,combustible gas, oil mist, steam,dripping or salinity etc.
Altitude 0~2000m
Derated use above 1000m, per 100m, the rated output current decrease 1%
Environment Temperature -10°C~40°C (Environment Temperature be 40°C~50°C, please keep derated use)
Humidity 5~95%, non-condensation
Vibration less than 5.9 m/s²(0.6G)
Storage Temperature -20°C~+70°C
Efficiency Rated Power Run≥93%
Installation Wall or rail mounting
Protectiion Grade IP20
Cooling Forced Air Cooling

Accessories:

1. GPRS (support 2g/3g/4g internet)

2. Output reactor

3. LCD keypad

LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance





LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance

Model Range

Drive Model Related Voltage Max DC input voltage (V) Rated output current (A) Applicable water pump (KW) SIZE
VFD500M-20T00150-PV 220V 800 7 1.5 SIZE A
VFD500M-20T00220-PV 220V 800 10.6 2.2 SIZE A
VFD500M-40T00150-PV 380V 800 4.2 1.5 SIZE A
VFD500M-40T00220-PV 380V 800 6 2.2 SIZE A
VFD500-20T00150-PV 220V 800 7 1.5 SIZE A
VFD500-20T00220-PV 220V 800 10.6 2.2 SIZE A
VFD500-20T00400-PV 220V 800 17 4 SIZE A
VFD500-40T00150-PV 380V 800 4.2 1.5 SIZE A
VFD500-40T00220-PV 380V 800 6 2.2 SIZE A
VFD500-40T00400-PV 380V 800 9.4 4 SIZE A
VFD500-40T00550-PV 380V 800 13 5.5 SIZE B
VFD500-40T00750-PV 380V 800 17 7.5 SIZE B
VFD500-40T01100-PV 380V 800 25 11 SIZE C
VFD500-40T01500-PV 380V 800 32 15 SIZE C
VFD500-40T01850-PV 380V 800 38 18.5 SIZE D
VFD500-40T02200-PV 380V 800 46 22 SIZE D
VFD500-40T03000-PV 380V 800 60 30 SIZE E
VFD500-40T03700-PV 380V 800 75 37 SIZE E
VFD500-40T04500-PV 380V 800 96 45 SIZE F
VFD500-40T05500-PV 380V 800 112 55 SIZE F
VFD500-40T07500-PV 380V 800 150 75 SIZE G
VFD500-40T09000-PV 380V 800 176 90 SIZE G
VFD500-40T11000-PV 380V 800 210 110 SIZE H
VFD500-40T13200-PV 380V 800 253 132 SIZE I
VFD500-40T16000-PV 380V 800 304 160 SIZE I
VFD500-40T18500-PV 380V 800 340 185 SIZE J
VFD500-40T20000-PV 380V 800 377 200 SIZE J

MPPT introduction

MPPT means Maximum Power Point Tracking; it’s a special function for solar system, which is used to get the

maximum possible power from one or more photovoltaic devices, typically solar panels. Solar panels have a

complex relationship between solar irradiation, temperature and total resistance that produces a nonlinear output

efficiency which can be analyzed based on the I-V curve. It is the purpose of the MPPT system to sample the output

of the cells and apply the proper resistance (load) to obtain maximum power for any given environmental conditions.

By adopting this technology in the solar pump inverter, it increases the working efficiency of solar panels,

and also adjusts the output frequency of solar pump VFD based on the sunshine strength; make sure the system

always works at an optimum condition.

Quality Control
VEIKONG solar pump VFDs have passed comprehensive test process during manufacturing.

R&D test: test the hardware and software performance, to make the design more optimization, makes sure the products have excellent

performance before production;

Board test: test the performance of every board in our products, to reduce product defective rate;

IQC: take strict quality inspection for every income components, to ensure every income components are qualified.

Aging test: make the solar pump VFDs at run status, put them in the aging test house at 50°C for 48 hours, to remove every unqualified products.

Load test: the last and the most important test, add different load to the solar pump VFDs, test their input and output value, to check their

working performance. unqualified products will be removed from the team.

By applying such strict testing process, VEIKONG ensures every outgoing solar pump VFD has excellent quality.


Product Tags:

MPPT VFD Solar Pump Inverter LCD

      

MPPT VFD Solar Pump Inverter IP20

      

LCD keypad solar pump vfd

      
Wholesale LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance from china suppliers

LCD MPPT VFD Solar Pump Inverter 400V DC Maximum Input Voltage for Optimal Performance Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Shenzhen Veikong Electric Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)